Digital Storage Oscilloscopes
Tektronix TDS1000C-EDU Series
|
 |
Features & Benefits
Key Performance Specifications
- 100 MHz, 60 MHz, 40 MHz Bandwidth Models
- 2 Channels
- Up to 1 GS/s Sample Rate on All Channels
- 2.5k Point Record Length on All Channels
- Advanced Triggers including Pulse Width Trigger and
Line-selectable Video Trigger
Ease-of-Use Features
- 16 Automated Measurements, and FFT Analysis for Simplified
Waveform Analysis
- Autoset and Signal Auto-ranging
- Probe Check Wizard
- 11-Language User Interface and Context-sensitive Help
- 5.7 in. (144 mm) Active TFT Color Display
- Small Footprint and Lightweight – Only 4.9 in. (124 mm) Deep
and 4.4 lb. (2 kg)
Connectivity
- USB 2.0 Host Port on the Front Panel for Quick and Easy Data
Storage
- USB 2.0 Device Port on Rear Panel for Easy Connection to a
PC or Direct Printing to a PictBridge®-compatible
Printer
3-year Warranty
Performance You Need at a Price You Can Afford
The TDS1000C-EDU Digital Oscilloscope Series is designed
specifically to meet the needs of today’s schools and
universities. Packed with features and built-in tools, the
TDS1000C-EDU is easy to learn and simple to operate – ideal for
first-time oscilloscope users and students. Featuring the same
user interface as other members of the Tektronix TDS Oscilloscope
Family, your students will learn to operate the world’s most
popular oscilloscope platform, with over 500,000 oscilloscopes in
operation worldwide.
To simplify integration with your existing curriculum, the
TDS1000C-EDU also includes an Education Resource CD filled with
tools to help your students master the use of an oscilloscope. The
TDS1000C-EDU offers the tools and performance you need at a price
you can afford.
Digital Precision for Accurate Measurements
With up to 100 MHz bandwidth and 1 GS/s maximum sample rate, no
other digital storage oscilloscope offers as much bandwidth and
sample rate for the price. Tektronix proprietary sampling
technology provides real-time sampling with a minimum of 10X
oversampling on all channels, all the time to accurately capture
your signals. Sampling performance is not reduced when using
multiple channels.
Critical Tools for Troubleshooting Your Device
Advanced triggers – rising/falling edge, pulse width, and video
– help you quickly isolate your signals of interest. Once you’ve
captured a signal, advanced math capabilities and automated
measurements can speed your analysis. Quickly perform an FFT or
add, subtract, or multiply waveforms. Sixteen automated
measurements quickly and reliably calculate important signal
characteristics such as frequency or rise time, while the built-in
Limit Test function enables you to easily identify problems in
your signal.
Designed to Make Your Work Easy
The TDS1000C-EDU Series oscilloscopes are designed with the
ease of use and familiar operation you have come to expect from
Tektronix.
Intuitive Operation
The intuitive user interface with dedicated per-channel
vertical controls, auto-setup, and auto-ranging makes these
instruments easy to use, reducing learning time and increasing
efficiency.
Help When You Need It, Where You Need It
The built-in Help menu provides you with important information
on your oscilloscope’s features and functions. Help is provided in
the same language as the user interface.
Probe Check Wizard
Check out your probe compensation before making measurements
with just one button that starts a fast, easy procedure.
Flexible Data Transfer
The USB host port on the front panel enables you to save your
instrument settings, screenshots, and waveform data in a flash.
Easy PC Connectivity
Easily capture, save, and analyze measurement results by
connecting to your PC with the rear-panel USB device port and the
included copy of OpenChoice® PC Communications
Software. Simply pull screen images and waveform data into the
stand-alone desktop application or directly into Microsoft Word
and Excel. Alternatively, if you prefer not to use your PC, you
can simply print your image directly to any PictBridge®-compatible
printer.
Performance You Can Count On
In addition to industry-leading service and support, every
TDS1000C-EDU Series oscilloscope comes backed with a 3-year
warranty as standard.
Education Resources
Every TDS1000C-EDU model includes an Education Resource CD
filled with tools to help your students master the use of an
oscilloscope. The Education Resource CD includes two Student Labs
and Instructor’s Guides, and two Primers. The Introduction to
Oscilloscopes Student Lab and Instructor’s Guide explains the
basics of oscilloscope operation complete with hands-on exercises
for your students. The Introduction to Oscilloscope Probes
Student Lab and Instructor’s Guide explains the fundamentals of
probing and how probes can affect measurement quality. The two
Primers included are the most popular and widely-used from
Tektronix – the XYZs of Oscilloscopes and ABCs of Probes.
Quickly and easily capture waveforms.
Included Education Resource CD is filled with tools to help
your students master the use of an oscilloscope.
Easily capture, save and analyze measurement results with
OpenChoice™ PC Communications Software.
Characteristics
TDS1000C-EDU Series Digital
Storage Oscilloscopes
| Characteristic |
TDS1001C-EDU |
TDS1002C-EDU |
TDS1012C-EDU |
| Display (QVGA) |
Color TFT |
Color TFT |
Color TFT |
| Bandwidth*1 |
40 MHz |
60 MHz |
100 MHz |
| Channels |
2 |
2 |
2 |
| External Trigger Input |
Included on all models |
| Sample Rate on each Channel |
500 MS/s |
1.0 GS/s |
1.0 GS/s |
| Record Length |
2.5k points at all time bases on all models |
| Vertical Resolution |
8 bits |
| Vertical Sensitivity |
2 mV to 5 V/div on all models with
calibrated fine adjustment |
| DC Vertical Accuracy |
±3% on all models |
| Vertical Zoom |
Vertically expand or compress a live or
stopped waveform |
| Maximum Input Voltage |
300 VRMS CAT II; derated at
20 dB/decade above 100 kHz to 13 Vp-p AC at 3 MHz |
| Position Range |
2 mV to 200 mV/div +2 V; >200 mV to 5 V/div
+50 V |
| Bandwidth Limit |
20 MHz for all models |
| Input Coupling |
AC, DC, GND on all models |
| Input Impedance |
1 MΩ in parallel with 20 pF |
| Time Base Range |
5 ns to 50 s/div |
5 ns to 50 s/div |
5 ns to 50 s/div |
| Time Base Accuracy |
50 ppm |
| Horizontal Zoom |
Horizontally expand or compress a live or
stopped waveform |
*1 Bandwidth is 20 MHz at 2 mV/div, all models.
| Characteristic |
TDS1001C-EDU |
TDS1002C-EDU |
TDS1012C-EDU |
| I/O Interfaces |
| USB Ports |
Included on all models: 2 USB 2.0 ports
USB host port on front panel supports USB flash drives
USB device port on back of instrument supports connection
to PC and all PictBridge-compatible printers |
| GPIB |
Optional |
| Nonvolatile Storage |
| Reference Waveform Display |
(2) 2.5k point reference waveforms |
| Waveform Storage without USB Flash Drive |
(2) 2.5k point |
(2) 2.5k point |
(2) 2.5k point |
| Waveform Storage with USB Flash Drive |
96 or more reference waveforms per 8 MB |
| Setups without USB Flash Drive |
10 front-panel setups |
| Setups with USB Flash Drive |
4000 or more front-panel setups per 8 MB |
| Screen Images with USB Flash Drive |
128 or more screen images per 8 MB (the
number of images depends on file format selected) |
| Save All with USB Flash Drive |
12 or more Save All operations per 8 MB A
single Save All operation creates 3 to 9 files (setup,
image, plus one file for each displayed waveform) |
Acquisition Modes
| Characteristic |
Description |
| Peak Detect |
High-frequency and random glitch capture. Captures
glitches as narrow as 12 ns (typical) using acquisition
hardware at all time-base settings from 5 μs/div to 50 s/div |
| Sample |
Sample data only |
| Average |
Waveform averaged, selectable: 4, 16, 64, 128 |
| Single Sequence |
Use the Single Sequence button to capture a single
triggered acquisition sequence at a time |
| Roll Mode |
At acquisition time base settings of >100 ms/div |
Trigger System
| Characteristic |
Description |
| Trigger Modes |
Auto, Normal, Single Sequence |
Trigger Types
| Characteristic |
Description |
| Edge (Rising/Falling) |
Conventional level-driven trigger. Positive or negative
slope on any channel. Coupling selections: AC, DC, Noise
Reject, HF Reject, LF Reject |
| Video |
Trigger on all lines or individual lines, odd/even or
all fields from composite video, or broadcast standards
(NTSC, PAL, SECAM) |
| Pulse Width (or Glitch) |
Trigger on a pulse width less than, greater than, equal
to, or not equal to, a selectable time limit ranging from
33 ns to 10 s |
Trigger Source
| CH1, CH2, Ext, Ext/5, AC Line. |
Trigger View
| Displays trigger signal while trigger view button is
depressed. |
Trigger Signal Frequency Readout
| Provides a frequency readout of the trigger source. |
Cursors
| Characteristic |
Description |
| Types |
Amplitude, Time |
| Measurements |
[Δ]T, 1[Δ]T (frequency), [Δ]V |
Automatic Waveform Measurements
| Period, Frequency, +Width, –Width, Rise Time, Fall Time,
Max, Min, Peak-to-Peak, Mean, Cycle RMS, RMS, Cursor RMS,
Duty Cycle, Phase, Delay. |
Waveform Math
| Characteristic |
Description |
| Operators |
Add, Subtract, Multiply, FFT |
| FFT |
Windows, Hanning, Flat Top, Rectangular, 2048 sample
points |
| Sources |
CH1 – CH2, CH2 – CH1, CH1 + CH2, CH1 × CH2 |
Autoset Menu
| Signal Type |
Autoset Menu Choices |
| Single-button, automatic setup of all
channels for vertical, horizontal, and trigger systems, with
undo Autoset. |
| Square Wave |
Single-cycle, Multi-cycle, Rising or Falling Edge |
| Sine Wave |
Single-cycle, Multi-cycle, FFT Spectrum |
| Video (NTSC, PAL, SECAM) |
Field: All, Odd, or Even Line: All or Selectable Line
Number |
Autorange
| Automatically adjust vertical and/or horizontal
oscilloscope settings when probe is moved from point to
point, or when the signal exhibits large changes. |
Display Characteristics
| Characteristic |
Description |
| Display |
QVGA color TFT |
| Interpolation |
Sin (x)/x |
| Display Types |
Dots, vectors |
| Persistence |
Off, 1 s, 2 s, 5 s, infinite |
| Format |
YT and XY |
Environmental
| Characteristic |
Description |
| Temperature |
| Operating |
0 °C to +50 °C |
| Nonoperating |
–40 °C to +71 °C |
| Humidity |
| Operating and Nonoperating |
Up to 80% RH at or below +40 °C. Up to 45% RH up to
+50 °C |
Regulatory
| Characteristic |
Description |
| Electromagnetic Compatibility |
Meets EMC Directive 2004/108/EC, meets EN61326 Class A;
meets Australian EMC Framework |
| Safety |
UL61010-1:2004 CSA, C22.2 No. 61010-1:2004,
EN61010-1:2001, IEC61010-1:2001. EU Low Voltage Directive
2006/95/EC |
Physical Characteristics
| Instrument |
| Dimension |
mm |
in. |
| Height |
158.0 |
6.2 |
| Width |
326.3 |
12.8 |
| Depth |
124.2 |
4.9 |
| Weight |
kg |
lb. |
| Instrument Only |
2.0 |
4.4 |
| with Accessories |
2.2 |
4.9 |
| Instrument Shipping |
| Package Dimensions |
mm |
in. |
| Height |
266.7 |
10.5 |
| Width |
476.2 |
18.7 |
| Depth |
228.6 |
9.0 |
| RM2000B Rackmount |
mm |
in. |
| Height |
482.6 |
19.0 |
| Width |
177.8 |
7.0 |
| Depth |
108.0 |
4.3 |
Ordering Information
| Model |
Description |
| TDS1001C-EDU |
40 MHz, 2 Ch, 500 MS/s, Color Digital Storage
Oscilloscope |
| TDS1002C-EDU |
60 MHz, 2 Ch, 1 GS/s, Color Digital Storage Oscilloscope |
| TDS1012C-EDU |
100 MHz, 2 Ch, 1 GS/s, Color Digital Storage
Oscilloscope |
Standard Accessories
| Accessory |
Description |
| TPP0101 |
Two (2) 100 MHz 10X passive probes |
| Power Cord |
(Please specify plug option) |
| NIM/NIST |
Traceable Certificate of Calibration |
| Documentation |
(Please specify preferred language option) |
| Educator Classroom and Lab Resource CD |
Contains lab experiments for oscilloscopes and probes,
and XYZs of Oscilloscopes and ABCs of Probes
Primers |
| OpenChoice® PC Communications Software |
Enables fast and easy communication between a Windows PC
and the TDS1000C-EDU Series through USB. Transfer and save
settings, waveforms, measurements, and screen images |
| 3-year Warranty |
Covering labor and parts for defects in materials and
workmanship for a minimum of 3 years, excluding probes and
accessories*2 |
*2 Probes and accessories are not covered by the
oscilloscope warranty and Service Offerings. Refer to the data
sheet of each probe and accessory model for its unique warranty
and calibration terms.
Recommended Accessories
| Accessory |
Description |
| TEK-USB-488 |
GPIB to USB converter |
| AC2100 |
Soft Carrying Case for Instrument |
| HCTEK4321 |
Hard Plastic Carrying Case for Instrument (requires
AC2100) |
| RM2000B |
Rackmount Kit |
| 077-0444-xx |
Programmer Manual – English Only |
| 077-0446-xx |
Service Manual – English Only |
| 174-4401-00 |
USB host to device cable, 3 feet long |
Power Plug Options
| Option |
Description |
| A0 |
North America power |
| A1 |
Universal Euro power |
| A2 |
United Kingdom power |
| A3 |
Australia power |
| A5 |
Switzerland power |
| A6 |
Japan power |
| A10 |
China power |
| A11 |
India power |
| A12 |
Brazil power |
| A99 |
No power cord or AC adapter |
User Manual Options
| Option |
Description |
| Translated front-panel overlays included
with their respective user manuals. |
| L0 |
English manual |
| L1 |
French manual |
| L2 |
Italian manual |
| L3 |
German manual |
| L4 |
Spanish manual |
| L5 |
Japanese manual |
| L6 |
Portuguese manual |
| L8 |
Standard Chinese manual |
| L9 |
Korean manual |
| L10 |
Russian manual |
Recommended Probes
| Probe |
Description |
| TPP0101 |
100 MHz 10X passive probes |
| TPP0201 |
200 MHz 10X passive probes |
| P2220 |
10X-1X switchable passive probe (200 MHz when 10X is
selected) |
| P6101B |
1X passive probe (15 MHz, 300 VRMS CAT II
rating) |
| P6015A |
1000X high-voltage passive probe (75 MHz) |
| P5100 |
100X high-voltage passive probe (250 MHz) |
| P5200 |
High-voltage active differential probe (25 MHz) |
| P6021 |
15 A, 60 MHz AC current probe |
| P6022 |
6 A, 120 MHz AC current probe |
| A621 |
2000 A, 5 to 50 kHz AC current probe |
| A622 |
100 A, 100 kHz AC/DC current probe/BNC |
| TCP303/TCPA300 |
150 A, 15 MHz AC/DC current probe/amplifier |
| TCP305/TCPA300 |
50 A, 50 MHz AC/DC current probe/amplifier |
| TCP312/TCPA300 |
30 A, 100 MHz AC/DC current probe/amplifier |
| TCP404XL/TCPA400 |
500 A, 2 MHz AC/DC current probe/amplifier |
Service Options*2
| Option |
Description |
| Opt. C3 |
Calibration Service 3 Years |
| Opt. C5 |
Calibration Service 5 Years |
| Opt. D1 |
Calibration Data Report |
| Opt. D3 |
Calibration Data Report 3 Years (with Option C3) |
| Opt. D5 |
Calibration Data Report 5 Years (with Option C5) |
| Opt. R5 |
Repair Service 5 Years |
*2 Probes and accessories are not covered by the
oscilloscope warranty and Service Offerings. Refer to the data
sheet of each probe and accessory model for its unique warranty
and calibration terms.
Service Offerings (Available after purchase)
| Option |
Description |
| TDS10xxC-EDU-R1PW |
Repair Service Coverage, 1 Year Post Warranty |
| TDS10xxC-EDU-R2PW |
Repair Service Coverage, 2 Years Post Warranty |
| TDS10xxC-EDU-R5DW |
Repair Service Coverage, 5 Years (includes product
warranty period). 5-year period starts at time of customer
instrument purchase |
The Tektronix Customer Service Advantage
You can trust Tektronix to offer unequalled engineering
expertise and a customer-centric approach to ensure the optimal
performance of your Tektronix products and maximize the lifetime
value of your Tektronix investment. With service from Tektronix
you get:
- Access to the source of product knowledge; unsurpassed
technical expertise
- Your challenges solved by front-line technical experts,
design engineering reinforcement, and online support tools
- Comprehensive and thorough support provided worldwide,
including software and firmware updates, data reports, and
adjustments
- Efficiency and convenience; no-hassle service from initial
service call to turnaround and delivery
- Flexible repair and calibration service with access to the
best on-call technical trouble shooting staff in the industry,
with over 20 years of training per support engineer
- Customer-centric approach dedicated to serving your needs
everyday with services designed to optimize your product
performance, increase productivity and ROI by delivering a fixed
cost of ownership, and efficient management of service
|
|
|
|
|
12335 World Trade Drive 7A
San Diego, CA 92128-3783 |
|